
| Quick answer: A peptide COA is the lab report for one batch of a research compound. Start by matching the product name, size and lot number on the COA to your vial or packaging. Then verify the report date and issuing laboratory. Next, check identity, where the mass detected by LC-MS should line up with the expected molecular weight, and purity, the HPLC percentage for the main peak. Measured net content reports the amount the lab found in the tested vial, and the endotoxin line gives a value in EU/mg. Finish by confirming the report with the lab that issued it. Its findings apply only to the sample that was tested, and only to laboratory research. |
You have a supplier’s COA open, and you need it to answer two things. Does it describe the vial on your bench, and do the numbers on it hold up?
The purity line answers only part of that. The rest sits in the lot number, the identity and content values, the endotoxin reading and the sign-off, and those lines only make sense read in order.
Below, we show how to read a peptide COA using one of our own AxisPharm reports for BPC-157. We go through it in the order you’d check any supplier’s report: identifiers first, then identity, purity, content and endotoxin.
After that, we cover what’s different on a blend report, the red flags that point to a weak or edited COA and how to confirm a report with the lab that issued it.
Key Takeaways
- Match the report to your vial before you read a single number. The product name, size and lot on the COA should match your vial. A missing or mismatched lot means the numbers belong to some other batch.
- Purity, detected mass and net content are not interchangeable. A batch can show 99.3% purity and measure 9.6 mg in a vial labeled 10 mg, because the two readings measure different things.
- A blend COA should identify every listed component separately. Look for an expected and a detected mass for each peptide. If per-component amounts or purity are missing, ask the supplier before you rely on the blend.
- Our AxisPharm reports are open to the same checks. The COA library holds signed certificates for the research compounds in our research catalog, so you can check the relevant lot before you order.
What a Peptide COA Is and Who Issues It
A peptide certificate of analysis (COA) is a lab’s report on one sample from one production lot. It says what was tested and how, what the lab found and who signed off on the values.
Part of learning how to read a certificate of analysis is checking who wrote it. An in-house COA comes from the manufacturer or seller testing its own product. A third-party COA comes from an independent lab with no stake in whether the batch sells.
| In-house COA | Third-party COA | |
| Tested by | The manufacturer or seller | An independent lab |
| Strength | Tracks quality at each production step | Gives an outside check on the finished batch |
| Weak point | The issuer has a stake in a passing report | Confirm the lab is named and reachable |
In-house testing has real value, because a manufacturer knows its own process and can test at every stage. It gives up independence, though. The party that wrote the report also profits from a good one.
Research Only sends every batch to AxisPharm, LLC, a third-party lab in the United States. The lab’s name sits at the top of every report.
Whoever issues it, the lot match ties a report’s findings to your material, and anything the report doesn’t list, it hasn’t tested. That’s why matching comes first.
Match the Report to Your Vial First
Start by checking the product name, size and lot number against your vial. Then verify the report date, issuing lab and sign-off. A mismatched lot means the reported values can’t be reliably applied to your material.

- Product name and size. The sample name should match your label exactly, including the amount. Our BPC-157 report reads BPC-157 10MG, so it can’t stand in for a different size or a blend.
- Lot number. Compare the report’s lot with your vial or its packaging, character for character. The current BPC-157 batch is lot RO-BC106.1.2026.
- Report date. It should come after the sample was received and fit the batch you bought. A report dated long before your batch was made describes an older lot.
- Issuing lab. The lab’s name should appear on the report itself, with enough detail for you to contact it.
- Signature. Someone at the lab should be named as responsible for the values. Ideally a second person, such as a quality assurance (QA) reviewer, signs off too.
We show the same identifiers on each product page. The BPC-157 listing carries the lot, the labeled and measured amounts and a link to the signed PDF, so the match takes a few seconds.
Check the lot on every order, because it’s the only way to tell whether a new vial came from the same batch as the last one. If a vial or its packaging shows no lot, ask the seller which lot shipped before you rely on any report.
Reading Each Section of a Peptide COA
Most COA peptide testing comes down to three tests. LC-MS checks identity, HPLC measures purity and the LAL test measures endotoxin, a bacterial contaminant.
Our AxisPharm reports run two pages. Page 1 holds the sample details, the sign-off and the instrument charts. Page 2 holds the values table, the endotoxin reading and a one-line conclusion. Open the current BPC-157 report in another tab and follow along.
Sample Details and Lot Number
The sample block identifies exactly what the lab received. For our BPC-157 lot, it reads BPC-157 10MG, brand name Research Only and lot RO-BC106.1.2026, with the receiving condition marked acceptable.
The block also lists two dates, MFD 06/2026 for manufacture and BBD 06/2028 for best before.
Read the lot one character at a time. Different sizes of one product can differ by a single digit, like our 10 mg and 20 mg WOLVERINE lots, RO-WOL106.1.2026 and RO-WOL206.1.2026.
Some lots have more than one report. Our BPC-157 lot has a June 19 report and the current one from September 25, which adds those two dates and a metals panel. The values the two share agree.
When a lot has multiple reports, confirm which is current and whether the newer document adds to or replaces the earlier one.
Identity by Expected and Detected Mass
Identity tells you whether the vial holds the compound named on the label. The lab checks it with LC-MS, an instrument that measures the mass of each molecule it detects.
The report sets two numbers side by side, the expected weight of the molecule and the mass the lab detected. On our BPC-157 report, those are 1419.5 g/mol and 1420.5 [M+H].
The one-unit gap is normal. [M+H] means the molecule was measured with one hydrogen ion attached, which gives it the charge the instrument needs to detect it. That ion adds about one unit.
Our reports label the detected ions, such as [M+H], but they don’t state the lab’s acceptance tolerance or explain how the ion assignments were validated. Ask the lab which reference mass and tolerance it used, especially if a detected value differs from the expected reading.
A mass match supports identity, but it doesn’t prove the full structure. Published 2016 recommendations on preparing peptides for this kind of testing note that a second round of mass spectrometry, called MS/MS, is needed to confirm a peptide’s sequence.

Purity as an HPLC Percentage
HPLC purity is the main peak’s share of the total UV signal. Our BPC-157 batch reads 99.3% at 220 nm.
To get that figure, HPLC runs the sample through a packed column, and its parts come out one at a time. Each part registers as a peak on the UV detector. The lab then divides the main peak’s area by the area of all the peaks combined.
The wavelength matters because it decides what the detector can see. Peptide bonds absorb UV light strongly around 220 nm, so that setting catches the target peptide and the impurities that matter most, such as shortened or altered copies of it.
On the chart, look for one tall, narrow peak over a flat baseline. On our BPC-157 trace, the main peak comes at about 2.46 minutes, with a few small blips beside it. Big extra peaks, or a bump on the main peak’s side, pull the percentage down.
Our chart can’t be used to check the math, though. It combines every wavelength the detector reads (it’s labeled TWC of DAD) and prints no peak areas or test conditions. You can see the peak’s shape, but you can’t recalculate 99.3% from it.
Purity also leaves things out. Counter-ion salts and water don’t show up at 220 nm, so they never enter the figure, and AxisPharm notes on our reports that salts and sugars aren’t counted as impurities. That’s why net content is reported separately.
Net Content Against the Labeled Amount
Net content is the amount the lab reports measuring in the tested vial. Our BPC-157 report gives 9.6 mg for a vial labeled 10 mg.
Set that next to the 99.3% purity figure and you have two different kinds of number. One is an amount and the other is a ratio, so one can’t stand in for the other.
Content can also mean different things. Synthetic peptides usually leave purification bound to small salt molecules called counter-ions. A 2020 review of these counter-ions treats peptide content, leftover water and the counter-ions themselves as separate quality checks.
The same 2016 recommendations define net peptide content as the peptide alone, without water or counter-ions. Labs usually measure it by breaking the peptide down and counting its building blocks, a method called amino acid analysis. Our report doesn’t name the method behind its 9.6 mg figure.
| Number on the COA | What it measures | BPC-157, lot RO-BC106.1.2026 | What it leaves out |
| Labeled amount | The nominal amount stated on the vial label | 10 mg | Whether the fill was accurate |
| Measured net content | Milligrams found in the vial the lab tested | 9.6 mg | How pure that peptide is |
| HPLC purity | Main peak share of the UV signal at 220 nm | 99.3% | How many milligrams are present |
If your assay requires a known peptide quantity, ask the lab what the net content figure includes and how it was measured.
Endotoxin and Other Panels
Endotoxins are fragments of bacterial cell walls that can linger in a sample. The standard way to measure them is the LAL test, covered by USP <85>, the Bacterial Endotoxins Test. The value comes in endotoxin units per milligram (EU/mg).
Our BPC-157 lot came in at 0.052 EU/mg. There’s no single pass mark for every compound or use, and our AxisPharm reports print the value without a pass or fail line. Compare it with the limit your assay calls for.
Some COAs add other panels, such as heavy metals or residual solvents. The September BPC-157 report adds a metals test (ICP-MS) for nine elements, such as lead and arsenic. AxisPharm lists every one under its 0.15 ppm detection limit.
Not every report carries that panel. Two other updated reports in our library do, while our June reports for WOLVERINE 10 mg and GLOW cover identity, purity, net content and endotoxin only. If a panel matters to your research, assess the listed values and the method behind them first.

Method References, Signatures and Dates
The method line tells you which instruments produced the numbers. The September BPC-157 report lists LCMS, LAL endotoxin assay and ICP-MS. It reports UV purity at 220 nm but doesn’t list the column or run conditions.
A purity figure with no stated method gives you no way to judge how it was measured.
Next, check that the dates fall in order. On that report, samples were received between June 8 and August 31, 2026, lab work ran from June 18 to September 25, and the report is dated September 25.
A report dated before its own sample arrived needs an explanation from the lab.
Then check who signed. Each of our reports names the lab technician who reported the values and carries the signature of the QA director who reviewed them. It also has a certificate ID you can quote to the lab, 25Sep2026-01 on the current BPC-157 report.
How to Evaluate the Values on a Peptide COA
There’s no universal set of passing criteria for research compounds. Assess each value against the lab’s documented methods and the specifications your research applies, and where a lab states its own limit, that limit comes first.
The table pulls the checks from this guide into one place, with our BPC-157 batch as the example.
| Line on the report | What to look for | Our BPC-157 batch |
| Lot and product | Same lot, name and size as your vial | RO-BC106.1.2026, BPC-157 10MG |
| Identity | Detected mass matches the expected weight within the lab’s tolerance, with the ion labeled | 1420.5 [M+H] against 1419.5 g/mol |
| Purity | Meets the supplier’s documented specification or the acceptance criteria your research requires, with the wavelength stated | 99.3% at 220 nm, against our advertised 99%+ |
| Net content | Close to the labeled amount, with the measurement method stated | 9.6 mg against 10 mg labeled, method not stated |
| Endotoxin | A value in EU/mg under the limit your assay requires | 0.052 EU/mg |
| Sign-off | Named analyst, reviewer and report date | Lab technician, QA director, September 25, 2026 |
Our 99%+ purity guarantee covers every batch. The reports in our library are how you hold us to it.
How to Read a Blend COA
A blend vial holds more than one peptide, so its COA has more to show. It should identify every listed peptide separately, because one matched mass says nothing about the others.
Ideally it also gives each component’s quantity and purity. One figure for the whole mixture can’t show how much of each peptide the vial holds.
Our WOLVERINE 10 mg report shows how this looks. It lists an expected weight for each peptide, 1419.5 g/mol for BPC-157 and 4963.4 g/mol for TB-500, with a detected value next to each.
BPC-157 reads 1420.5 [M+H], the same single-charge pattern as before. TB-500 is a much bigger peptide, so it shows up as two readings, 1243.1 [M+4H] and 994.3 [M+5H].
Large molecules can pick up several hydrogen ions at once. The instrument then records the mass divided by the charge, so an [M+4H] reading is the peptide’s mass plus four hydrogen ions, divided by four.
For multiply charged readings like these, ask the lab which reference mass, charge states and tolerance it applied before you count them as a match.
Net content on that report reads 9.3 mg in total, split 4.6 and 4.7 mg between the two peptides. One purity figure, 99.3%, covers the whole blend.

GLOW and KLOW follow the same layout with three and four components. GLOW lists expected weights of 403.5, 1419.5 and 4964.0 g/mol, and KLOW adds 342.5 g/mol for KPV, each with its own detected value.
| Blend | Components with an identity line | UV purity at 220 nm, whole blend | Measured net content |
| WOLVERINE 10 mg | BPC-157, TB-500 | 99.3% | 9.3 mg, split 4.6 and 4.7 mg |
| GLOW 70 mg | GHK-Cu, BPC-157, TB-500 | 99.4% | 68.3 mg total |
| KLOW 80 mg | GHK-Cu, BPC-157, TB-500, KPV | 99.3% | 76.3 mg total |
Our blend reports list expected and detected masses for each component and give one purity figure for the whole blend. WOLVERINE adds a weight for each component. GLOW and KLOW give one total weight, and none of the three reports purity by component.
If your work depends on the amount of a single component inside a blend, ask us what the current report covers before you order.
On any blend COA, count the identity lines. The count should match the number of peptides on the label.
Red Flags on a Peptide COA
Each of these problems leaves a visible sign on the page.
- No lot number. The sample line names the product and no batch, so the report could belong to any vial the seller has shipped.
- No lab name. The header carries the seller’s logo and no lab, which leaves nobody outside the seller to confirm the values.
- One report across several products. The same certificate ID, date or chromatogram shows up on different product pages, sometimes with only the name changed.
- Old or disordered dates. The report predates the batch you bought, or the received, testing and report dates fall out of order.
- Purity with no identity test. A high HPLC figure appears with no detected mass, so the report confirms something is pure without confirming what it is.
- No supporting data. A detected mass or purity figure appears with no method, plot or peak data behind it. That’s a reason to request more documentation, though it doesn’t prove the report is false.
- Signs of an edited PDF. Fonts or spacing change inside the value cells, a signature sits over text, or figures drift off the table grid.
Any unexplained mismatch or missing information should be resolved with the issuing lab first. A lot that doesn’t match your vial rules a report out entirely.
How to Verify a COA Is Real
To verify a peptide COA, take it back to the lab that issued it. Anyone who handles a PDF can edit it, and the lab’s own records are the one copy a seller can’t touch.
- Note the lab, the report ID and the lot. Write down the lab name, the certificate or task number and the lot exactly as printed.
- Use the lab’s verification tool if it has one. Some labs let you enter the report’s task number and a key printed on it. Finnrick checks a seven-character certificate ID once you sign in. Its certificates leave out vendor name and batch ID, so match those with the seller.
- Contact the lab when there’s no portal. Send the certificate ID, the lot and the values you see, and ask whether they match the lab’s records. For a Research Only certificate, that lab is AxisPharm, which you can reach through its contact page.
- Match the confirmed lot to your vial. A genuine report for a different lot still doesn’t describe your material.
Confirmation from the issuing lab verifies that the certificate is authentic. Matching the lot number connects the reported findings to the identified batch, although the findings still apply only to the tested sample. Do both when a new supplier’s vial reaches your bench, before the first assay.
What a COA Doesn’t Cover
A COA describes one sample at one point in time, so it can’t speak for other batches or for handling after the sample left the lab. Each lot needs its own report, and storage conditions belong on the label and product page.
A COA says nothing about use. Research Only compounds are for in-vitro and laboratory research by qualified professionals, not for human or veterinary use. The same research-only limit appears on every page of AxisPharm’s reports.
If your work calls for GMP-grade material, custom synthesis or bulk volumes, our catalog isn’t built for it. A research-use COA won’t replace the documentation that work needs. And if a vial ever looks inconsistent with its report, our FAQ explains how we investigate quality issues at batch level.
Check Our Reports Against Your Vial
Our COA library groups the signed AxisPharm reports by compound. Each one links to its product page, so you can open the report for the batch you’re considering and read it line by line before you order.
For questions about a specific lot or what a report covers, contact our team with the lot number.
Peptide COA FAQ
What Is a COA for Peptides?
A COA for peptides is the lab report for a single production lot of a peptide. It lists the lot number, the tests run, the measured identity, purity and content values, and the lab that signed it. It applies to that lot only.
How Much Does a Peptide COA Cost?
Third-party testing is priced per sample and per panel, so costs vary by compound and test. Finnrick is one example. Its product testing page lists basic fees of $118 to $198 per compound, with free community testing for eligible products and paid add-ons for endotoxin and heavy metals.
We commission AxisPharm to test every batch, so our reports come with the product at no extra cost.
Where Can I Get a COA for Peptides?
Ask the seller for the report that matches your lot, and expect a third-party COA for every batch. Ours are public in our COA library and linked from each product page. You can also send a sample to an independent lab and receive a report in your own name.
How Do I Know if a Peptide COA Is Legit?
Check that the lot, product and size match your vial, that a named lab and signatory appear, and that identity and purity are reported with identifiable test methods and sufficient supporting documentation.
Then confirm the certificate ID with the issuing lab or its verification portal. A report that passes both checks is genuine for that lot.
What Does [M+H] Mean on a Peptide COA?
[M+H] means the lab measured the molecule with one hydrogen ion attached, so the detected value reads about one unit above the expected molecular weight. On our BPC-157 report, 1420.5 [M+H] sits against an expected 1419.5 g/mol.
References
- AxisPharm. Test Report/Certificate of Analysis: BPC-157 10MG, Lot RO-BC106.1.2026. September 25, 2026.
- Hoofnagle AN, Whiteaker JR, Carr SA, et al. Recommendations for the generation, quantification, storage, and handling of peptides used for mass spectrometry-based assays. Clin Chem. 2016;62(1):48-69. doi:10.1373/clinchem.2015.250563
- Sikora K, Jaśkiewicz M, Neubauer D, Migoń D, Kamysz W. The role of counter-ions in peptides: an overview. Pharmaceuticals (Basel). 2020;13(12):442. doi:10.3390/ph13120442
- United States Pharmacopeial Convention. <85> Bacterial endotoxins test. In: United States Pharmacopeia and National Formulary (USP-NF). 2017. doi:10.31003/USPNF_M98830_02_01
- Shimadzu Corporation. Ionization and mass separation. Basics of Liquid Chromatography-Mass Spectrometry. Accessed November 12, 2026.
- AxisPharm. Test Report/Certificate of Analysis: WOLVERINE 10MG, Lot RO-WOL106.1.2026. June 19, 2026.